: Provides three-phase control of the mains (including asymmetry) and single-phase control of the generator with RMS readings.
The IP40 or IP54 protection level (depending on model) makes it suitable for standard electrical cabinets. 2. Wiring the CT (Current Transformer) The CT must be placed on the main phase ( L1cap L sub 1 L2cap L sub 2 L3cap L sub 3 ) the connection to the capacitor bank. Crucial: Ensure the CT ratio ( ) is correctly programmed in the controller's settings. 3. Voltage Inputs Connect the voltage measurement inputs ( ) through protection fuses. Match the voltage phase to the CT phase. 4. Step Output Wiring
The device is engineered to monitor both engine and alternator functions while managing the transfer of load between the mains and the generator. Comprehensive Supervision
Single-phase generator measurement, three-phase mains measurement.
Specifically designed for 24VDC battery systems, with an operational range typically between 13V and 33VDC .
Built-in RS232 port for remote control, troubleshooting, and programming via a computer. Why You Need a "Better" Lovato 31 RGAM 24 Manual PDF
To prevent immediate battery system error warnings upon initial system startup, the controller must be properly calibrated via its setup menus. Physical Keypad Programming
Fully adjustable minimum/maximum voltage limits ranging from 0.7 to 1.2 Ue . Four Main Operating Modes
The Lovato 31 RGAM 24 is a three-phase generator designed for industrial and commercial applications. It features a robust design, high-efficiency engine, and advanced control system. The generator is capable of producing high-quality power, making it suitable for use in various industries, including construction, healthcare, and data centers.
: Instructions for remote control and supervision software on step-by-step programming for this controller? Control unit for generating sets RGAM series
The are microprocessor-based control units designed for automatic standby generating sets [8†L7-L9]. They serve as the brain of a generator system, constantly monitoring the mains power supply and automatically starting the generator when a fault is detected. This is known as the Automatic Mains Failure (AMF) function, a key feature that ensures your critical loads never lose power for long [3†L18-L20][15†L8-L9].
Single-phase tracking from 70VAC to 624VAC .
[Mains Failure Sensed] ➔ [Pre-Heat / Glow Plugs Activated] ➔ [Fuel Solenoid Opens] ➔ [Starter Motor Engaged (StA)]
An administrative override sequence designed to verify generator health. Activating TEST immediately fires the starter sequence and runs the engine at its nominal operating speed without interrupting the live utility load. However, if the primary utility grid fails while the unit is executing a TEST block, the controller immediately forces an emergency changeover to feed the facility. Critical Parameter Groups and Menu Navigation
: Standard 144x144 mm front-panel mounting enclosure.